Erratum
Article Outline
In the October, 2011 issue, errors were discovered in Table 1 in the article “Radiation Therapy for Liver Metastases” [Semin Radiat Oncol 21(4):264-270] by Tracey E. Schefter, MD, and Brian D. Kavanagh, MD. The table appears on page 268 of the issue. Please see corrected table below.
Table 1. SBRT for Liver Metastases: Outcomes
| Patients | Lesions | SBRT (PTV dose) | PTV | Time Point | Local Control | Comments | |
|---|---|---|---|---|---|---|---|
| Heidelberg, 200448⁎ | 37 | 60 | 11-21 Gy × 1 | GTV + 6 mm axial + 10 mm sup-inf | 18 |
<16 Gy: 0% >16 Gy: 81% | |
| Wuerzburg, 200649 | 39 | 51 |
7 Gy × 4 10 Gy × 3 12.5 Gy × 3 26 Gy × 1 | GTV + 8 mm axial + 13 mm sup-inf | 2 |
28-30 Gy: 58% >30 Gy: 82% P < 0.01 | |
| Aarhus, Copenhagen, 200650⁎ | 44 | Not stated | 10 Gy × 3 | GTV + 5 mm axial + 10 mm sup-inf | 2 | 79% | 3 ulcer, intestinal dose >30 Gy |
| Erasmus U, Rotterdam, 201051 | 20 | 31 |
12.5 Gy × 3 (18 pts) 15 Gy × 3 (2 pts) | Individualized | 2 | 74% | 1 late portal HTN in multiply treated patient |
| Colorado/multi-institutional, 200930⁎ | 47 | 63 | 12-20 Gy × 3 | GTV + 5 mm axial + 10 mm sup-inf | 2 |
≤3 cm: 100% >3 cm: 77% P = 0.015 | |
| PMH, 200931⁎ | 68 | 141 |
Variable, NTCP-based Median 7 Gy × 6 | Individualized (5 mm minimum) | 1 | 71% | Dose response for LC |
| Stanford, 201046⁎ | 19 | 33 | 18-30 Gy × 1 | ITV + 3-5 mm or GTV + 5-10 mm without 4D-CT | 1 | 77% | |
| University of Texas Southwestern Medical Center, 201032⁎ | 26 | 35 | 6 Gy × 5 | ITV + 5 mm | 2 | 30 Gy: 56% | |
| 10 Gy × 5 | 50 Gy: 89% | ||||||
| 12 Gy × 5 | 60 Gy: 100% |
⁎ Prospective study. |
PII: S1053-4296(11)00115-9
doi:10.1016/j.semradonc.2011.11.001
© 2012 Elsevier Inc. All rights reserved.
Refers to article:
- Radiation Therapy for Liver Metastases