« Previous
Next »
Seminars in Radiation Oncology
Volume 16, Issue 4
, Pages 239-248
, October 2006
Radiotherapy of Mobile Tumors
References
- Computed tomography guided management of interfractional patient variation . Semin Radiat Oncol . 2005;15:168–179
- . Artifacts in computed tomography scanning of moving objects . Semin Radiat Oncol . 2004;14:19–26
- . 4-dimensional computed tomography imaging and treatment planning . Semin Radiat Oncol . 2004;14:81–90
- Synchronized moving aperture radiation therapy (SMART): Improvement of breathing pattern reproducibility using respiratory coaching . Phys Med Biol . 2006;51:617–636
- . Errors and margins in radiotherapy . Semin Radiat Oncol . 2004;14:52–64
- Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion . Int J Radiat Oncol Biol Phys . 2005;61:1535–1550
- Temporo-spatial IMRT optimization: Concepts, implementation and initial results . Phys Med Biol . 2005;50:2779–2798
- Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation . Int J Radiat Oncol Biol Phys . 1999;45:603–611
- Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer . Int J Radiat Oncol Biol Phys . 2000;48:1175–1185
- The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer . Int J Radiat Oncol Biol Phys . 2000;48:81–87
- Evaluation of deep inspiration breath-hold lung treatment plans with Monte Carlo dose calculation . Int J Radiat Oncol Biol Phys . 2002;53:1058–1070
- The use of active breathing control (ABC) to reduce margin for breathing motion . Int J Radiat Oncol Biol Phys . 1999;44:911–919
- Active breathing control (ABC) for Hodgkin’s disease: Reduction in normal tissue irradiation with deep inspiration and implications for treatment . Int J Radiat Oncol Biol Phys . 2000;48:797–806
- Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy . Int J Radiat Oncol Biol Phys . 2003;56:704–715
- Three-dimensional evaluation of intra- and interfraction immobilization of lung and chest wall using active breathing control: A reproducibility study with breast cancer patients . Int J Radiat Oncol Biol Phys . 2003;57:968–978
- Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation . Int J Radiat Oncol Biol Phys . 2003;55:392–406
- Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center . Med Phys . 2000;27:346–353
- Irradiation synchronized with respiration gate . Int J Radiat Oncol Biol Phys . 1989;17:853–857
- . Respiration gated radiotherapy treatment: A technical study . Phys Med Biol . 1996;41:83–91
- . A comparison of beam characteristics for gated and nongated clinical x-ray beams . Med Phys . 1999;26:2086–2091
- Clinical efficacy of respiratory gated conformal radiation therapy . Med Dosim . 1999;24:115–119
- . Compatibility of Varian 2100C gated operations with enhanced dynamic wedge and IMRT dose delivery . Med Phys . 2000;27:1732–1738
- Respiratory gated irradiation system for heavy-ion radiotherapy . Int J Radiat Oncol Biol Phys . 2000;47:1097–1103
- Determining parameters for respiration-gated radiotherapy . Med Phys . 2001;28:2139–2146
- Potential radiotherapy improvements with respiratory gating . Australas Phys Eng Sci Med . 2002;25:1–6
- Real-time tumour-tracking radiotherapy . Lancet . 1999;353:1331–1332
- Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers . Int J Radiat Oncol Biol Phys . 2000;48:1591–1597
- Detection of lung tumor movement in real-time tumor-tracking radiotherapy . Int J Radiat Oncol Biol Phys . 2001;51:304–310
- Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy . Int J Radiat Oncol Biol Phys . 2003;56:240–247
- Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor . Int J Radiat Oncol Biol Phys . 2000;48:435–442
- Physical aspects of a real-time tumor-tracking system for gated radiotherapy . Int J Radiat Oncol Biol Phys . 2000;48:1187–1195
- Real-time tumor-tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy . Cancer . 2002;95:1720–1727
- . Technical aspects of image-guided respiration-gated radiation therapy . Med Dosim . 2006;31:141–151
- . Tracking moving organs in real time . Semin Radiat Oncol . 2004;14:91–100
- Image-guided robotic radiosurgery . Neurosurgery . 1999;44:1299–1306 discussion 1306-1307
- Robotic motion compensation for respiratory movement during radiosurgery . Comput Aided Surg . 2000;5:263–277
-
Real-time tracking of the tumor volume in precision radiotherapy and body radiosurgery—A novel approach to compensate for respiratory motion
. 2000;
Proceedings of the 14th International Conference on Computer Assisted Radiology and Surgery (CARS 2000). June 28-July 1,. San Francisco, CA
- Patterns of patient movement during frameless image-guided radiosurgery . Int J Radiat Oncol Biol Phys . 2003;55:1400–1408
- . Fiducial-based targeting accuracy for external-beam radiotherapy . Med Phys . 2002;29:334–344
- Motion adaptive x-ray therapy: A feasibility study . Phys Med Biol . 2001;46:1–10
- Synchronized moving aperture radiation therapy (SMART): Average tumour trajectory for lung patients . Phys Med Biol . 2003;48:587–598
- Aperture maneuver with compelled breath (AMC) for moving tumors: A feasibility study with a moving phantom . Med Phys . 2004;31:760–766
-
.
The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery
.
Math Comput Model
. 2003;37:735–745
- . Synchronized delivery of DMLC intensity modulated radiation therapy for stationary and moving targets . Med Phys . 2005;32:1802–1817
- . DMLC leaf-pair optimal control for mobile, deforming target . Med Phys . 2005;32:275–285
- Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking . Med Phys . 2005;32:942–951
- Determination of maximum leaf velocity and acceleration of a dynamic multileaf collimator: Implications for 4D radiotherapy . Med Phys . 2005;32:932–941
- . The effect on IMRT conformality of elastic tissue movement and a practical suggestion for movement compensation via the modified dynamic multileaf collimator (dMLC) technique . Phys Med Biol . 2005;50:1163–1190
- . Limitations of a simple technique for movement compensation via movement-modified fluence profiles . Phys Med Biol . 2005;50:N155–N161
- . Real-time intra-fraction-motion tracking using the treatment couch: A feasibility study . Phys Med Biol . 2005;50:4021–4033
-
.
“4D” IMRT delivery
.
In:
Bortfeld T
, Schmidt-Ullrich R
, De Neve W
, et al.
editor.
Image-Guided IMRT
. Germany, Springer: Heidelberg; 2005;p. 269–288
- Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker . Med Phys . 2003;30:505–513
- Patient training in respiratory-gated radiotherapy . Med Dosim . 2003;28:7–11
- . Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment . Semin Radiat Oncol . 2004;14:65–75
- Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system . J Appl Clin Med Phys . 2001;2:191–200
- Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging . Int J Radiat Oncol Biol Phys . 2002;52:522–531
- Respiratory gating for liver tumors: Use in dose escalation . Int J Radiat Oncol Biol Phys . 2003;55:659–668
- Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy . Int J Radiat Oncol Biol Phys . 2002;53:822–834
- Calculation of rotational setup error using the real-time tracking radiation therapy (RTRT) system and its application to the treatment of spinal schwannoma . Int J Radiat Oncol Biol Phys . 2002;54:939–947
- Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT) . Radiother Oncol . 2002;62:275–281
- Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions . Int J Radiat Oncol Biol Phys . 2002;53:1117–1123
- Reduction in acute morbidity using hypofractionated intensity-modulated radiation therapy assisted with a fluoroscopic real-time tumor-tracking system for prostate cancer: Preliminary results of a phase I/II study . Cancer J . 2003;9:268–276
- Intrafractional tumor motion: Lung and liver . Semin Radiat Oncol . 2004;14:10–18
- High dose three-dimensional conformal boost (3DCB) using an orthogonal diagnostic X-ray set-up for patients with gynecological malignancy: A new application of real-time tumor-tracking system . Radiother Oncol . 2004;73:219–222
- Three-dimensional conformal setup (3D-CSU) of patients using the coordinate system provided by three internal fiducial markers and two orthogonal diagnostic X-ray systems in the treatment room . Int J Radiat Oncol Biol Phys . 2004;60:607–612
- Application of real-time tumor-tracking and gated radiotherapy system for unresectable pancreatic cancer . Yonsei Med J . 2004;45:584–590
- Feasibility of synchronization of real-time tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy . Int J Radiat Oncol Biol Phys . 2004;60:335–341
- The effect of tumor location and respiratory function on tumor movement estimated by real-time tracking radiotherapy (RTRT) system . Int J Radiat Oncol Biol Phys . 2005;63:164–169
- Insertion and fixation of fiducial markers for setup and tracking of lung tumors in radiotherapy . Int J Radiat Oncol Biol Phys . 2005;63(5):1442–1447
- Real-time monitoring of a digestive tract marker to reduce adverse effects of moving organs at risk (OAR) in radiotherapy for thoracic and abdominal tumors . Int J Radiat Oncol Biol Phys . 2005;61:1559–1564
- Integrated radiotherapy imaging system (IRIS): Design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors . Phys Med Biol . 2004;49:243–255
- Anatomic feature-based registration for patient set-up in head and neck cancer radiotherapy . Phys Med Biol . 2005;50:4667–4679
- A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode . Phys Med Biol . 2005;50:3669–3679
- Prediction of respiratory tumour motion for real-time image-guided radiotherapy . Phys Med Biol . 2004;49:425–440
-
.
Adaptive filtering to predict lung tumor breathing motion during image-guided radiation therapy
. 2002;
Proceedings of the 16th International Conference on Computer Assisted Radiology (CARS 2002). Paris, France, June 26-29, 2002
- Predicting respiratory motion for four-dimensional radiotherapy . Med Phys . 2004;31:2274–2283
- Accuracy of a wireless localization system for radiotherapy . Int J Radiat Oncol Biol Phys . 2005;61:933–937
- Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers . Phys Med Biol . 2005;50:4481–4490
PII: S1053-4296(06)00033-6
doi: 10.1016/j.semradonc.2006.04.007
© 2006 Elsevier Inc. All rights reserved.
« Previous
Next »
Seminars in Radiation Oncology
Volume 16, Issue 4
, Pages 239-248
, October 2006